Open Loop vs Closed Loop Laser Power ControlSource:Jinan Jing CNC CO.,Ltd Open-loop laser control sets current, voltage or duty cycle according to a command and assumes the output follows. Closed-loop control measures a signal and adjusts the drive to reduce error. Open-loop behavior It is simpler and common in many industrial sources. Aging, temperature and contamination can change output even when the command remains fixed. Closed-loop behavior A photodiode or other detector samples output and provides feedback. This can stabilize power against slow drift and improve process repeatability. The sampled signal must represent actual output accurately. A detector may monitor the source before delivery optics, so losses or dirty windows downstream still affect the workpiece. Periodic external calibration remains necessary. Quick answers • Does closed loop guarantee constant power at the part? Not if downstream optics change. • Can feedback correct instant pulse problems? Response bandwidth limits what it can correct. • Is open-loop unacceptable? Many stable processes use it with regular verification. |