NEWS
让价值共享 记录企业发展脚步

Open Loop vs Closed Loop Laser Power Control

Author:Jinan Jing CNC CO.,LtdSource:Jinan Jing CNC CO.,Ltd

Open-loop laser control sets current, voltage or duty cycle according to a command and assumes the output follows. Closed-loop control measures a signal and adjusts the drive to reduce error.

Open-loop behavior

It is simpler and common in many industrial sources. Aging, temperature and contamination can change output even when the command remains fixed.

Closed-loop behavior

A photodiode or other detector samples output and provides feedback. This can stabilize power against slow drift and improve process repeatability.

The sampled signal must represent actual output accurately. A detector may monitor the source before delivery optics, so losses or dirty windows downstream still affect the workpiece.

Periodic external calibration remains necessary.

Quick answers

• Does closed loop guarantee constant power at the part? Not if downstream optics change.

• Can feedback correct instant pulse problems? Response bandwidth limits what it can correct.

• Is open-loop unacceptable? Many stable processes use it with regular verification.

0086-15954568354
info@jingcnc.com
https://wa.me/+8615954568354
JINAN  JING CNC CO.,Ltd